TEM Asbestos Air Analysis

Advanced Airborne Asbestos Analysis Using TEM

Advanced Airborne Asbestos Analysis Using TEM

Transmission Electron Microscopy, commonly called TEM, is a highly sensitive method used to identify and quantify asbestos structures collected from air samples.

TEM provides the magnification and analytical detail needed to evaluate structures that may be too small to characterize using conventional light microscopy.

Michigan’s NVLAP-Accredited TEM Laboratory — Lab Code 201028-0

ETL is the only laboratory in Michigan accredited through the National Institute of Standards and Technology’s National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 201028-0) for airborne asbestos analysis under 40 CFR Part 763, Subpart E, Appendix A.

NVLAP Lab Code: 201028-0

Accreditation applies to the testing activities identified in ETL’s current scope of accreditation. NVLAP accreditation, Lab Code 201028-0, is a finding of laboratory competence and does not constitute product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. government.

Greater Sensitivity for Airborne Asbestos Identification

TEM uses an electron beam to examine asbestos structures at significantly higher magnification than conventional light microscopy. This allows the analyst to evaluate smaller structures and distinguish asbestos from certain non-asbestos materials.

Smaller Asbestos Structures

TEM can evaluate asbestos structures that may be too small to observe or characterize using light microscopy.

Asbestos-Specific Identification

TEM provides analytical capabilities that help distinguish asbestos from non-asbestos structures that may appear similar under lower magnification.

Detailed Project Documentation

TEM results provide documented analytical findings for regulated clearance projects, asbestos management programs, and complex airborne fiber investigations.

Supporting AHERA Asbestos Compliance

The Asbestos Hazard Emergency Response Act, commonly called AHERA, establishes asbestos inspection, management, and response-action requirements for public and private nonprofit elementary and secondary schools.

Following certain asbestos response actions, AHERA requires air samples to be evaluated using the mandatory TEM method in 40 CFR Part 763, Subpart E, Appendix A.

AHERA-Related TEM Analysis May Support

  • Post-abatement clearance following asbestos response actions
  • Public and private nonprofit K–12 school projects
  • Documentation of response-action completion
  • School asbestos management programs
  • Air-quality evaluation following regulated asbestos work
  • Consultant and contractor project closeout requirements

When Is TEM Required?

TEM is required for certain AHERA response-action clearances in covered schools. It may also be specified for other projects requiring asbestos-specific identification, greater analytical sensitivity, or detailed characterization of airborne structures.

Choosing Between PCM and TEM

PCM and TEM provide different types of information. The appropriate method depends on the project, applicable requirements, and the analytical detail needed.

PCM Analysis

  • Reports airborne fiber concentration
  • Widely used for occupational exposure monitoring
  • Supports active remediation projects
  • Does not positively identify every fiber as asbestos

TEM Analysis

  • Provides asbestos-specific identification
  • Evaluates smaller structures
  • Provides greater analytical sensitivity
  • Supports applicable AHERA clearance requirements

Not Sure Which Method Your Project Requires?

ETL can explain the analytical differences between PCM and TEM. The project consultant or other qualified professional should determine the required sampling plan, analytical method, and clearance criteria.

TEM Support for Regulated and Complex Projects

ETL works with environmental consultants, asbestos professionals, remediation contractors, schools, and public agencies. Our laboratory supports individual clearance events as well as larger asbestos management and response-action programs.

AHERA Clearance

Airborne asbestos analysis supporting applicable post-abatement clearance requirements in covered schools.

Complex Investigations

Detailed analysis for projects requiring asbestos-specific identification or greater sensitivity.

Project Documentation

Clear laboratory reporting for clearance records, management plans, and project closeout documentation.

Submitting TEM Air Samples to ETL

TEM air samples may be mailed or delivered directly to ETL. Each submission should include a completed Chain of Custody with the project, sample, and collection information needed for laboratory processing and reporting.

Prepare Your TEM Submission

  • Select “Air (TEM)” under the asbestos analysis section.
  • Clearly label every cassette to match the Chain of Custody.
  • Provide the required project and sampling information.
  • Identify whether the samples are associated with AHERA clearance.
  • Include applicable field blanks and project controls.
  • Specify the requested analytical method and turnaround time.
  • Contact ETL before submitting time-sensitive clearance samples or large batches.

Mail or deliver samples to:
Environmental Testing Laboratories
37575 W. Huron River Drive
Romulus, Michigan 48174

Download the ETL Chain of Custody Form

Frequently Asked Questions

Environmental Testing Laboratories

Request Laboratory Services

Need laboratory analysis? Tell us about your samples and the testing you need.

Laboratory Services Request Form

ETL Laboratory
Scroll to top